Overview & Clinical Applications
The Stress Test Electrodes are listed as disposable stress test/ECG electrodes in 1 1/2 in foam with 10% chloride wet gel, sold 60 per pouch and 600 per case, with aggressive adhesive for motion-free diagnostic stress testing.
▸ Packaging 60 per pouch, 600 per case, as listed.
▸ Gel Ag/AgCl high chloride wet gel, hydrates the skin for fast, clear tracings, as listed.
▸ Adhesive Aggressive adhesive keeps electrodes on the patient, no motion artifact or repeat testing, as listed.
Technical Specifications & Features
| Component | Detail |
|---|---|
| Product Type | Disposable Stress Test/ECG Electrodes |
| Reorder Number | AIM5-60 |
| Material | 1 1/2 in foam, 10% chloride wet gel; Ag/AgCl; polyurethane reticulated foam sponge |
| Electrode Mix | 10 varying-size electrodes: 4ea. 2.25 in round foam wet gel, 4ea. 1.5 in teardrop foam wet gel, 1ea. 1.75 in x 1.625 in perforated foam wet gel electrode (2 square electrodes), as listed |
| Packaging | 60 per pouch; 600 per case; resealable pouch Yes; packaging size 12.5 x 7.75 x 8.75 in / 31.75 x 19.685 x 22.225 cm; size 8 x 12 in / 20.32 x 30.48 cm |
| Sensor | Diameter 0.42 in / 10.592 mm; substrate thickness 0.063 in / 1.588 mm; total surface area 1.7972 in² / 45.649 mm²; gel area 0.3068 in² / 7.7927 mm²; adhesive area 1.4904 in² / 37.8562 mm² |
| Electrical | ACZ impedance 32 Ohm; DC voltage offset 0.38 mV; SDR slope 0.07 mV/s; ACZ impedance repeat 25 Ohm; COIIN 7 uV; bias current tolerance 7 mV |
| Safety | Hypoallergenic adhesive; latex free; ISO 10993 passed; CE Mark according to MDD 93/42/EEC; RoHS Yes; REACH Yes; halogenated hydrocarbon content None; phthalate derivative content None |
| Shelf Life | 18 months |
| Use | Pediatric No; X-ray translucent No; repositionability No; integrated abrader No |
Compatibility & System Fit
Listed for use with GE, Marquette, Quinton, Burdick, Mortara, Norav, Cambridge, Nasiff, and Schiller systems. No other system compatibility is stated; confirm fit with an AIM Cardio expert before ordering.
• Check Before Ordering: Confirm the included accessories and configuration with an AIM Cardio expert before ordering.
Included Hardware & Accessories
Stress Test Electrodes: As listed.
Sold as: 60 per pouch; 600 per case.
Not claimed as included: No leadwires are included (lead wire length N/A). Confirm with an AIM Cardio expert.
AIM Cardio Testing & Warranty Coverage
Tested Before Shipping — AIM Warranty & Guarantee
Every system is tested, run, and cycled before shipping to help ensure proper operation, and is backed by the AIM Cardio Warranty and Guarantee. Contact our specialists to confirm configuration and coverage for your order.
FAQ — Stress Test Electrodes Monitoring Electrode
What are these electrodes?
Disposable stress test/ECG electrodes in foam with wet gel, as listed.
How are they sold?
60 per pouch and 600 per case, as listed.
What is the reorder number?
AIM5-60, as listed.
Are they latex free?
Yes, latex free with hypoallergenic adhesive, as listed.
What should I confirm before ordering?
Confirm the included accessories and configuration with an AIM Cardio expert before ordering.





