ge case, ge case system, ge treadmill
ge case, ge case system, ge treadmillGE

GE Case 6.7 Stress Test & T2100 TREADMILL

Call 800.333.9111 for sale price

GE Case V 6.7 Stress Test & T2100 Treadmill

GE CASE V6.7 with Software
Standard with LAN, XML, and PDF exporting options for easy EMR or EHR connectivity

GE T2100 Stress Test Treadmill
T2100 Treadmill, 220V ,Full Handrail Set, and Emergency Stop Included

GE Case & Treadmill  has Service Contracts and Extended Warranties available
Please inquire for applications  and probes of each unit.

Call Us Today! 800.333.9111

Product Description

Ge Case has 1 Year Parts and Labor Warranty

The GE Case stress test:
• ECG Analysis Frequency: 500 Hz
• ST Measurements: ST amplitudes, slope, integral, index, ST/HR slope, ST/HR loops, ST/HR index up to 15 leads
• E, J and Post-J Point: Manual or computer selected
• Signal Processing: Incremental median updating technique
• Baseline Correction: Finite Residual Filter (FRF) and/or Cubic Spline analysis
• QRS Detection and Analysis: Automatic or manual lead selection
• ECG Output: Real-time ECG/QRS beep/TTL synchronization output
• Heart Rate: Automatic arrhythmia detection, documentation and annotation
• Full-Disclosure ECG: Beat-to-beat ECG storage & event review
• Reanalysis: Post-test medians measurements from E, J and post-J point selections
• ECG Interpretation (Optional): Marquette* 12SL* resting ECG analysis program for adults and pediatrics
• Additional ECG Function: XTI stress interpretation; Vectorcardiography (15 lead)

GE Case Data Aquisition:
• Technology: Active, “Type BF” floating isolated powered 14-channel acquisition module with built-in lead-fail detection and lead prep impedance measurement
• Sampling Rate: Over-sampling @ 4000 Hz
• Dynamic Range: 320 mV, ± 10 mV signal superimposed on ± 150 mV DC offset
• Resolution: 4.88 μV/LSB @ 500 Hz
• Noise: < 15 μV peak-to-peak noise over 0.01 to 150 Hz (-3 dB) bandwidth • Frequency Response: -3 dB, display and writer • High-Pass Filter: 0.01 (or 0.05 Hz, special use) with DC offset control • Low-Pass Filter: 20, 40, 100, 150 Hz (selectable) • Line Filter: 50.0 or 60.0 Hz notch filter (selectable) • Baseline Correction: Cubic Spline algorithm • Artifact/Baseline Correction: Finite Residual Filter (FRF) analysis • Common Mode Rejection: > 140 dB (123 dB with AC filter disabled)
• Input Impedance: > 10 M Ohms @ 10 Hz, defibrillator protected
• Patient Leakage: < 10 μA • Pace Detect: Orthogonal LA, LL and V6; 750 μV @ 50 μs Communications/Storage Options: • MUSE* systems compatible via diskette; network (optional) • MUSE Web compatible for retrieval view and printing of MUSE system data • Local storage: Minimum 40 GB hard drive storage of complete ECG record and test results • PDF export of final reports with auto naming protocols also from Microsoft® Word and Excel • XML export of specified data • CASE* network server with editing workstations • Windows® XP operating system Display: • Display Type: LCD (flat panel display) • Display Resolution (Minimum): LCD-1280 x 1024 • Display Size: 17 or 19-inch LCD • Monitored Leads: 3, 6, 12 or 15 • Displayed Leads: Number on screen 3, 6, 12 or 15 • Display Format: 3 rhythm, 3 rhythm + medians, 3 rhythm + trends, 6 rhythm, 4 x 2.5 + 1 rhythm, 2 x 6 • Display Speeds 25, 50 mm/s • Display Sensitivity/Gain: 2.5, 5, 10, 20 mm/mV • Displayed vital Signs Data (Configurable): Heart rate, target heart rate, blood pressure, exercise clock, stage clock, phase clock, protocol, speed, grade, Watts, METS, RRP and SpO2 • Displayed data ST scan/median complexes, arrhythmias, ventricular ectopic/min counter, 3 to 12 lead waveforms, lead check torso and 12 leads, waterfall display, trends, tabular summary, stored ECG strips, interpretation, time-of-day clock, patient name, warning messages and prompts Writer: • Writer Technology: “Instant” load, thermal dot array • Writer Leads: 3, 6, 12 or 15 leads (standard, NEHB, Cabrera, configurable) • Writer Speeds: 5, 12.5, 25 and 50 mm/sec (± 2%) • Writer Sensitivity/Gain: 2.5, 5, 10 or 20 mm/mV (± 5%) • Writer Resolution: Horizontal 1000 lines/sec x 200 dpi dedicated local printing. 200 x 200 dpi generic printing • Paper Type: Thermal, perforated, fan-fold, 300 sheets/pack • Paper Size: A size 214.63 x 280 mm (8.45 x 11 in); A4 size 210 x 297.5 mm (8.27 x 11.0 in) Physical Specifications: • Height: 148 cm (58 in) with no monitor installed • Width: 62 cm (24 in) with paper tray removed • Depth: 75 cm (30 in) • Weight 68 kg (150 lb) without monitor Minimum Server Requirements: • Microprocessor: Pentium® ! 1.6 GHz • RAM: 256 MB • Hard Drive: > 40 GB
• Operating system: Windows 2000 Server; Windows 2003 Server

GE Case Interfaces Included:
• Acquisition module
• Keyboard (PS/2) anti dedicated stress keypad (USB)
• Mouse (PS/2)
• Built-in thermal printer (USB)
• 100 Mbps ethernet MUSE compatible
• 6 serial ports: (COM 1-2, COM A-D) treadmill, BP, ergometer, SpO2
• 4 analog and 1 TTL (trigger) output analog ergometer, camera sync, etc.
• Diskette drive: 3 1/2 in, 1.44 MB
• PC-compatible for data storage
• CD-R/W drive: readable for software updates; archivable data optional

GE Case Electrical Power:
• Power Supply: AC operation only
• Operating voltage range 100-120 VAC, 50-60 Hz, 2.8 A; 200-240 VAC, 50-60 Hz, 1.4 A
• Power consumption 350 W max (1200 BTU/hr); < 250 W normal (850 BTU/hr); < 30 W standby (100 BTU/hr)

GE Case Operating Conditions:
• Temperature: +10 to 40°C (+50 to 104°F)
• Humidity: 20 to 95% RH non-condensing

GE Case Storage/Transport Conditions:
• Temperature -40 to +70°C (-40 to 158°F); Paper discoloration may occur at high temperatures
• Humidity: 15 to 95% RH non-condensing

Option-Extended Warranty Available